Model No. |
CZ1206- :P=with PFC ,N=without PFC :E=EU
AC plug,U=US AC plug,K=UK AC plug ,A=Australia AC plug. |
Output |
Charge Voltage |
14.4Vdc+/-2% @ normal mode
13.7Vdc+/-2% @ floating mode
14.7Vdc+/-2% @ snow mode (when temperature under 0 °C
and AGM batteries use only) |
Charge Current Range |
0.8A~1.2A@ Motorcycle mode Selection by mode switch.
3.7A ~4.3A@ Car mode Selection by mode switch.
5.5A~6.2A@ Truck/Van mode Selection by mode switch. |
Rated Maximum Power |
88W |
Ripple & Noise (max) |
200mV |
Efficiency |
81% |
Battery Draining Current |
<0.2mA |
Voltage Tolerance |
±2% |
6 Charge steps |
Step1 |
Desulphation:Desulphation will pulse and revive sulphated batteries. |
Step2 |
Soft start:the charging current is limited for checking the situation and features of batteries. |
Step3 |
Bulk:main charging step provides most of current to speed up the charging. |
Step4 |
Absorption:terminal voltage maintains at original level and current drops after battery charged full. |
Step5 |
Analysis:charger tests the charging situation of charged batteries. |
Step6 |
Float:maintains a charged battery. |
Input |
Input Voltage range |
90~130 (US type), 170V~260V(EU type) |
Input frequency range |
47~63Hz |
Input current rating |
2.4A@110VAC / 1.2A@230VAC |
Power Factor Correction |
PFC >0.95.(Optional) |
Leakage Current |
<1mA / 240 Vac |
Protections |
Polarity Reverse |
YES.(NO Charge till fault has removed) |
Disconnect |
YES.(NO Charge and sparks when clips disconnect or short) |
Over Temperature |
Charger recovers aotomatically after fault condition has removed. |
Short Circuit |
YES.(NO Charge till fault has removed) |
Wrong Battery Protection |
YES.(No Charge When Vbat<2v or Vbat>15.5v) |
Environment |
Operating Temperature |
-20~50°C .Output power is reduced automatically at higher temperature. |
Operating Humidity |
10~95% RH. |
Vibration |
10~500HZ,2G/P-P,3 axes,15min sweep without malfunction. |
Shock |
20G/Package |